Switch Amplifier KCD2-SR-Ex1.LB

KCD2-SR-Ex1.LB
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • Relay contact output
  • Fault relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Folhas de dados: Dados técnicos do  KCD2-SR-Ex1.LB

General specifications
Signal typeDigital Input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3
Supply
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Ripple≤ 10 %
Rated current≤ 37 mA
Power dissipation≤ 750 mW
Power consumption≤ 750 mW
Input
Connection sidefield side
Connectionterminals 1+, 2-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Pulse/Pause ratiomin. 20 ms / min. 20 ms
Output
Connection sidecontrol side
Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Output Isignal ; relay
Output IIsignal or fault message ; relay
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delay≤ 20 ms / ≤ 20 ms
Mechanical life107 switching cycles
Transfer characteristics
Switching frequency≤ 10 Hz
Galvanic isolation
Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EUEN 61010-1:2010+A1:2019+A1:2019/AC:2019
Conformity
Electromagnetic compatibilityNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018
Degree of protectionIEC 60529:1989+A1:1999+A2:2013
Functional safetyIEC/EN 61508:2010
InputEN 60947-5-6:2000
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Height119 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificateBASEEFA 06 ATEX 0092 X
MarkingEx-Hexagon II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
InputEx ia
Voltage10.5 V
Current13 mA
Power34 mW (linear characteristic)
Supply
Maximum safe voltage253 V AC (Attention! Um is no rated voltage.)
Output
Contact loadingZone 2 : 50 V AC/2 A/cos φ > 0.75; 30 V DC/2 A resistive load
Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.)
Fault indication output
Maximum safe voltage40 V DC (Attention! Um is no rated voltage.)
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019
International approvals
UL approvalE106378
Control drawing116-0477 (cULus)
IECEx approval
IECEx certificateIECEx BAS 06.0025 X
IECEx markingEx ec nC [ia Ga] IIC T4 Gc
[Ex ia Da] IIIC
[Ex ia Ma] I
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210121
ECLASS 12.027210121
ECLASS 11.027210121
ECLASS 10.0.127210121
ECLASS 9.027210121
ECLASS 8.027210121
ECLASS 5.127210121
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: KCD2-SR-Ex1.LB

Datasheet: KCD2-SR-Ex1.LB

DatasheetTipo de ArquivoTamanho do Arquivo
Datasheet KCD2-SR-Ex1.LBPDF1220 KB
Fiche de données KCD2-SR-Ex1.LBPDF1256 KB
Datenblatt KCD2-SR-Ex1.LBPDF1220 KB
Datasheet KCD2-SR-Ex1.LBPDF1302 KB
Hoja de datos KCD2-SR-Ex1.LBPDF1231 KB

Documents: KCD2-SR-Ex1.LB

ManualsTipo de ArquivoTamanho do Arquivo
ManualPDF3685 KB
HandbuchPDF3693 KB
Instruction manuals
ИнструкцииPDF171 KB
Instruction manual / BetriebsanleitungPDF326 KB
Návod k poużitíPDF166 KB
Instruktions manualPDF164 KB
Instruction manualPDF171 KB
KasutusjuhendPDF162 KB
KäyttöohjePDF160 KB
Manuel d'instructionsPDF168 KB
BetriebsanleitungPDF172 KB
Οδηγίες χρήσηςPDF175 KB
HandleidingPDF166 KB
Instruction manual / BetriebsanleitungPDF164 KB
Használati útmutatóPDF167 KB
Manuale di istruzioniPDF166 KB
Lietošanas pamācībaPDF165 KB
Instrukciju vadovasPDF166 KB
Instrukcja obsługiPDF168 KB
Manual de instruçõesPDF167 KB
Manual de utilizarePDF166 KB
Návod na poużitiePDF166 KB
Navodila za uporaboPDF163 KB
Manual de instruccionesPDF167 KB
ManualPDF162 KB
Application reports
Application Report - Biological Cleaning of Wastwater and Secondary Sedimentation StagePDF566 KB
Application Report - Energy Generation in Wastwater Treatment PlantsPDF532 KB
Application Report - Generating Electricity in Coal-Fired Power PlantsPDF412 KB
Application Report - Sand Trap and Preliminary Sedimentation StagePDF448 KB
Application Report - Screening Systems in Sewage Treatment PlantsPDF577 KB
Application Report - Sicherer Brennstofftransport in KohlekraftwerkenPDF391 KB
Application Report - Water Inlet in Wastewater Treatment PlantsPDF526 KB
Applikationsbericht - Biologische Abwasserreinigung und NachklärungPDF568 KB
Applikationsbericht - Energiegewinnung in KläranlagenPDF535 KB
Applikationsbericht - Rechenanlagen in KläranlagenPDF578 KB
Applikationsbericht - Sandfang und VorklärungPDF434 KB
Applikationsbericht - Sicherer Brennstofftransport in KohlekraftwerkenPDF393 KB
Applikationsbericht - Stromerzeugung in KohlekraftwerkenPDF416 KB
Applikationsbericht - Wasserzulauf in KläranlagenPDF527 KB
Documents
Functional Safety ManualPDF2003 KB
Handbuch funktionale SicherheitPDF2016 KB

CAD+CAE: KCD2-SR-Ex1.LB

CADTipo de ArquivoTamanho do Arquivo
CAD 3-D / CAD 3-DSTP3088 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZEDZ1849 KB

Approvals+Certificates: KCD2-SR-Ex1.LB

CertificatesTipo de ArquivoTamanho do Arquivo
Australia New Zealand SIMTARS Group IPDF258 KB
Baseefa IECEx Certificate of ConformityLINK---
Brasil TUV Rheinland BrazilPDF1291 KB
Canada UL cULLINK---
Canada UL cULLINK---
China SITIIAS CCC Ex CertificatePDF1338 KB
DNV MarinePDF114 KB
Europe Baseefa ATEX Category (1) D ATEX Category 3 (1) G ATEX Category (M1)PDF137 KB
India PESO (India) CCOEPDF83 KB
Korea KOSHAPDF178 KB
USA ULPDF321 KB
USA ULLINK---
USA ULLINK---
United Arab Emirates SGS Gulf Limited ECASExPDF603 KB
United Kingdom Baseefa UK-Type Examination CertificatePDF136 KB
Worldwide TUV Rheinland Functional Safety CertificatePDF620 KB
Control Drawings
Control drawing UL / Control drawing ULPDF130 KB
Declaration of Conformity
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)PDF98 KB
EU Declaration of Conformity (P+F)PDF183 KB
EU Declaration of Conformity (P+F)PDF181 KB
EU Declaration of Conformity (P+F)PDF178 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF176 KB
EU Declaration of Conformity (P+F)PDF176 KB
EU Declaration of Conformity (P+F)PDF177 KB
EU-Konformitäterklärung (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF184 KB
EU Declaration of Conformity (P+F)PDF176 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF177 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF176 KB
EU Declaration of Conformity (P+F)PDF177 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF178 KB
EU Declaration of Conformity (P+F)PDF178 KB
EU Declaration of Conformity (P+F)PDF180 KB
EU Declaration of Conformity (P+F)PDF178 KB
EU Declaration of Conformity (P+F)PDF177 KB
EU Declaration of Conformity (P+F)PDF177 KB
EU Declaration of Conformity (P+F)PDF180 KB

Produtos Relacionados: KCD2-SR-Ex1.LB

Matching System Components

Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indicationpa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 2 m (6 foot), simple to customize to application space, Eliminates daisy-chainspa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 0.8 m (2.6 ft), simple to customize to application space, Eliminates daisy-chainspa
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 1.6 m (5 foot), simple to customize to application space, Eliminates daisy-chainspa
Cable trunking is integrated in the mounting profile, Safe spacious separation of safe and hazardous signals, No additional cable guides necessary, Standard length 1.8 m (5.8 ft), simple to customize to application space, With mounting aidspa
Cable trunking with integrated Power Rail UPR-03, Safe spacious separation of safe and hazardous signals, No additional cable guides necessary, Provides DC supply voltage to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aidspa
Accessories
1-channel, Dry contact input, For line fault detection (LFD)pa
2-pin screw terminal, For KC modules of K-System, Packaging unit: 5 pieces greenpa
2-pin screw terminal, For KC modules of K-System, Packaging unit: 5 pieces bluepa
Coding of K-System terminal blocks, Coding of LB/FB-System front sockets, Packaging unit: 20 x 6 coding pinspa
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.